Files
STM32F4-Base/test/host/iec104_netmcu/results/report.json
T
wandering1 90cc9a7d99 feat(iec104): 把 104 骨架完整迁到 MCU 板端并在台架跑通总召
把 IEC104 从模拟器端整体搬到板端:协议栈原先由独立 iec104Task 驱动,
现在改为 netTask 单 owner 的 threadless 驱动,退役独立任务。

驱动与后端:
- 新增 iec104_net_mcu.c/.h,实现 IEC104_Net.h 的 11 个 ABI 函数,
  用槽表加单调句柄映射 net_socket 的单 fd 模型;CLIENT 拆除只走
  net_drop_conn_locked,绝不 net_close 监听 fd。
- net_socket 增 5 个 owner-only 接口(net_accept_locked、
  net_drop_conn_locked、net_pending_bytes、net_send_try、
  net_mono_now_ms)。
- iec104_serv.c 重写为 iec104_serv_net_tick(),在 netTask 1ms 主循环
  里驱动 core;无 osDelay/阻塞调用,喂狗是第一句。
- Src/freertos.c 删除 iec104Task 三件套,对应栈水位探针表项同步删除。

内存:目标板 192KB SRAM 装不下 vendor 默认容量档,按实测裁剪到
skeleton 档(TCP 缓冲、业务池、SOE 256->128、值槽密集化),
RW_IRAM1 118,408 B / 90.3%,留 2,178 B 余量。

台架修复(只在真硬件暴露):
- SNTP s_ctx.fd 零初始化后为 0,而 net fd 0 是合法槽位下标,
  首次代次变化时误 net_close(0) 关掉 ftpTask 的监听槽,导致 104
  连接被 FTP 的 220 banner 抢走;改为显式 .fd = -1。
- Accept 幂等:单 fd 模型下 vendor 每轮重试 Accept 会拿到同一 fd,
  后端改为会话在役时返 WOULD_BLOCK,Close 不再清槽。

验证:
- Keil 全量重建 0 error 0 warning,uvprojx 零抖动。
- 模拟器真实 TCP 13/13、transport 10/10。
- netmcu 后端单测 13/13(新增 N12)。
- 台架 serial-boot-test required 全中;板端 2404 总召 129 帧收到
  59 遥信(53 有源、全 IV)+ 16 双点 + 30 遥测(PT1 三相非零、
  UN/频率/温度按未标定置 IV)、遥控选择执行全否定、校时 COT 7。
- 期间顺带修正 UI 漂移自检文案、.serialtest required 陈旧项、
  coding-standard 对 vendor 与外部 ABI 名字的排除口径。
2026-11-18 10:29:18 +08:00

45 lines
1.4 KiB
JSON

{
"scope": "REAL backend App/protocol/iec104/iec104_net_mcu.c + fake net layer; host-only isolation evidence, not full core/TcpServer/hardware",
"backend_sha256": "4d6b8d9e8ed3404372f274d99c16bc87a06fecbee8db0b30b044b24d0562d73d",
"sources": {
"MATRIX.md": "e8c913cac2a852173f052ce806a3da101a272e2a4dff8751499fdcf39788deab",
"net_socket_fake.h": "d597375d1186b4801b4dc859401b6f3f0c9d1110efda37d0a9e73b810d7a8cd0",
"net_socket_fake.c": "8eb9ea5ed195b38e2f4993ac021ad19afa40464ff03de73628d3a795350a631e",
"netmcu_test.c": "09c203941c41fbb543580f45192c1604b984daaeb10135548756d4e42e8ebe02",
"check_static.py": "8f08695a6c6bffec6047558b5b6d0aff0c7393665853357d1176f61b1aac1132"
},
"case_count": 13,
"case_count_basis": "13 named cases; N2a/N2b are two cases in one N2 test function",
"case_names": [
"N1",
"N2a",
"N2b",
"N3",
"N4",
"N5",
"N6",
"N7",
"N8",
"N9",
"N10",
"N11",
"N12"
],
"result": {
"build_rc": 0,
"run_rc": 0,
"failures": 0,
"failed_cases": [],
"note": ""
},
"bad_variants": "NOT_RUN for real backend; TEST DOUBLE B1..B7 evidence retained in results_stub/report.json",
"not_run": [
"full IEC104 STARTDT over core/TcpServer",
"board CH395F",
"MCU timing/WCET"
],
"known_deviations": [
"NODELAY: App/protocol/iec104/iec104_net_mcu.h comment; CH395F has no setsockopt, treated as always no-Nagle and NOT an OK condition"
]
}