Files
STM32F4-Base/IEC60870-Slave/test/periodic_scan_interop_test.py
T
STF bdcc8b6500
CI / L0 静态门禁 (pre-commit) (push) Failing after 7m46s
CI / L0.5 主机侧单测 (MSVC) (push) Successful in 21s
添加遥控、参数装载、文件传输等业务
2026-11-16 22:19:17 -08:00

96 lines
4.2 KiB
Python

"""Optional c104/lib60870-C master checks against the real scan fixture.
Usage: python periodic_scan_interop_test.py server.exe lib60870_client.exe
The c104 package is a test-only dependency; no production source imports it.
可选互操作编排:分别使用c104与原生lib60870-C主站验证Type20/21、COT1/2和SQ=0/1。
外部主站独立解析本库子站的报文;普通C专项和Node回环不依赖这两个客户端。
"""
import importlib.metadata
import pathlib
import subprocess
import sys
import time
import c104
def c104_client(port: int, sequence: bool) -> None:
errors = []
seen = set()
client = c104.Client(tick_rate_ms=50)
connection = client.add_connection(ip="127.0.0.1", port=port, init=c104.Init.NONE)
station = connection.add_station(common_address=1)
def receive(point: c104.Point, previous_info: c104.Information,
message: c104.IncomingMessage) -> c104.ResponseState:
try:
typ = int(point.type)
cot = int(message.cot)
assert message.common_address == 1 and message.originator_address == 0
assert message.is_sequence == sequence
assert message.number_of_objects == 2
assert not message.is_test and not message.is_negative
assert (typ == 20 and cot == 2) or (typ == 21 and cot in (1, 2))
index = point.io_address - (100 if typ == 20 else 200)
assert index in (0, 1)
if typ == 20:
assert isinstance(point.info, c104.StatusAndChanged)
assert point.info.status.value == 0x1234 + index, repr(point.info)
assert point.info.changed.value == 0x40 + index, repr(point.info)
assert point.quality == c104.Quality.Invalid
else:
assert abs(float(point.value) - (0.5 if index == 0 else -0.25)) < 0.0001
assert point.quality.is_good
seen.add((typ, cot, point.io_address))
except Exception as exc:
errors.append(f"{type(exc).__name__}: {exc}; type={point.type}, info={point.info}")
return c104.ResponseState.SUCCESS
for typ, addresses in ((c104.Type.M_PS_NA_1, (100, 101)), (c104.Type.M_ME_ND_1, (200, 201))):
for ioa in addresses:
station.add_point(io_address=ioa, type=typ).on_receive(callable=receive)
client.start()
try:
end = time.monotonic() + 5
while len(seen) < 6 and not errors and time.monotonic() < end:
time.sleep(0.02)
assert not errors, errors
assert len(seen) == 6, f"Missing parsed points: {seen}"
finally:
client.stop()
print(f"c104 {importlib.metadata.version('c104')} SQ={int(sequence)}: PASS Type20/21 COT1/2 IOA/value/quality")
def run(server: str, external: str, sequence: bool, use_c104: bool) -> None:
process = subprocess.Popen([server, str(int(sequence)), "6500"],
stdout=subprocess.PIPE, stderr=subprocess.PIPE,
text=True, creationflags=subprocess.CREATE_NO_WINDOW)
try:
line = process.stdout.readline().strip()
assert line.startswith("PORT "), line
port = int(line.split()[1])
if use_c104:
c104_client(port, sequence)
else:
result = subprocess.run([external, str(port), str(int(sequence))],
capture_output=True, text=True, timeout=8,
creationflags=subprocess.CREATE_NO_WINDOW)
assert result.returncode == 0, result.stdout + result.stderr
print(result.stdout.strip())
stdout, stderr = process.communicate(timeout=8)
assert process.returncode == 0 and not stderr, stdout + stderr
finally:
if process.poll() is None:
process.kill()
process.communicate()
if __name__ == "__main__":
if len(sys.argv) != 3:
raise SystemExit("Usage: python periodic_scan_interop_test.py server.exe lib60870_client.exe")
server_path, client_path = (str(pathlib.Path(p).resolve()) for p in sys.argv[1:])
for seq in (False, True):
for python_client in (False, True):
run(server_path, client_path, seq, python_client)